This article aimed to solve the battery problems with the X100 pad 2 series.
Recently, we received some feedback from our customer about the X100 Pad 2 series battery problem. If your X100 pas can't boot up, you can try this way.
The Xtooltech engineer finally solved the problem:
Tools required:
Static bracelet
Hot air gun (Temperature set up: 350±10℃)
Here are the procedures:
Precautions:Please wear the static bracelet before the operation
1. Disassemble the C6 capacitor and desolder a 4.7K 0603 resistor. Figure 1
Figure 1-1
Figure 1-2
Figure 1-3
2. Disassemble the Q14 transistor. Figure 2
Figure 2-1
Figure 2-2
3. Replace the C123 capacitor witth a 3.3K%5 0402 resistor. Figure 3